Workplace Restrooms: Everything You Need to Know.
Publication date: 13 July 2025
Ill-conceived restroom solutions in offices lead to real problems: long lines, discomfort, poor hygiene, and sometimes even… violations of building codes. It’s not just about compliance with regulations. Restrooms in the workplace affect comfort, efficiency, and how employees and visitors perceive the company. If you manage office space, design interiors, or are responsible for health and safety, it’s definitely worth learning more.
We’ve compiled key legal requirements, data, and best practices to help you ensure that your restroom facilities are functional and compliant—without guesswork and without risk.
What regulations govern the design of restrooms in the workplace?
When designing restrooms in office spaces, we must operate within a precisely defined legal framework. The regulations leave little room for interpretation—they specify both the minimum dimensions and the required fixtures, the number of units, and accessibility for specific user groups. Familiarity with these regulations is essential if we want to avoid design errors and issues during technical inspections.
The most important legal act governing the design of restrooms in office buildings is the Regulation of the Minister of Infrastructure dated April 12, 2002, on the technical requirements to be met by buildings and their location (Journal of Laws 2019, item 1065, as amended). Of particular importance here are sections § 81 through § 85, which address the general principles for the design of restroom facilities in buildings. They include provisions regarding the number of toilets and sinks depending on the building’s purpose and the number of users, requirements for public buildings, and specific conditions for facilities accessible to people with disabilities.
Section 87 also deserves special attention, as it precisely specifies the minimum dimensions of a toilet stall—that is, its width, depth, and the manner in which the door opens. This section also specifies how stalls should be located within rooms and sets out requirements for ventilation and lighting. Section 90, in turn, concerns hygiene and sanitation facilities—including restrooms and bathrooms for employees—and specifies their spatial requirements and accessibility.
The second legal basis that must be taken into account is the Regulation of the Minister of Labor and Social Policy of September 26, 1997, on general occupational safety and health regulations (Journal of Laws 2003 No. 169, item 1650, as amended). Sections 20–26 of this regulation set forth detailed requirements for hygiene and sanitation facilities in workplaces. There you will find, among other things, guidelines regarding the minimum number of toilets and sinks, their placement in relation to workstations, the obligation to provide separate facilities for women and men, as well as requirements related to adapting the space to the needs of people with disabilities.
These provisions are supplemented by the provisions of the Labor Code (Journal of Laws 1974, No. 24, item 141, as amended), in particular Article 207 and Article 232. These regulations require employers to ensure safe and hygienic working conditions, which includes providing access to functional, clean, and user-friendly restrooms. Failure to comply with these regulations may result in consequences in the event of an inspection by the State Labor Inspectorate or a health inspection.
Although they are not legally required, it is also advisable to follow technical and industry standards, which provide precise technical guidelines for the design of plumbing systems and restroom facilities. For example:
- PN-EN 12056 – a standard concerning the gravity drainage of wastewater from buildings, which is important for the design of sewer systems,
- PN-B-10425:1991 – a standard that provides detailed recommendations regarding the dimensions of restroom spaces, taking into account accessibility, ergonomics, and user comfort.
It is also worth consulting the recommendations of the National Institute of Hygiene (PZH), the General Office of Building Supervision (GUNB), and local Sanepid offices, which often provide supplementary and interpretive guidelines that are useful in cases of doubt or unusual situations.
In summary, the regulations are specific, and understanding them helps avoid basic design mistakes. But just as important as the letter of the law is its practical interpretation—ergonomics, comfort, and functionality. These factors determine whether an office restroom will actually serve employees on a daily basis.
How many restrooms per employee?
One of the most common mistakes made when designing office spaces is treating restrooms as a secondary consideration. However, from the perspective of comfort, workplace hygiene, and regulatory compliance, the proper planning of the number and layout of restroom facilities is of fundamental importance.
Pursuant to § 26 of the Regulation of the Minister of Labor and Social Policy dated September 26, 1997, on general occupational safety and health provisions, the number of restrooms at a workplace should be determined based on the number of employees and the type of work performed.
For small teams—up to 10 people—one restroom stall and one sink are sufficient. For larger groups of employees, the regulation stipulates that at least one restroom stall must be provided for every additional 20 employees of the same sex. This means that in a mixed-gender team of, for example, 40 people (20 women and 20 men), you need at least two stalls for women and two for men, plus an appropriate number of sinks.
The regulation also allows for the use of a shared coed restroom, but only if you employ up to 5 people of the same sex and provided that the stall is properly designed (fully enclosed, ensures privacy, and is ventilated).
If your employees perform work that is dirty, physically demanding, or potentially harmful to their health, you are also required to provide showers and changing rooms. In such cases, the number and equipment are determined on a case-by-case basis, but there must be at least one shower for every eight people who need to use it after work.
It’s important to remember that merely meeting the minimum legal requirements is not the same as ensuring a comfortable work environment. In addition to the number of employees, consider the following:
- traffic volume during rush hour,
- frequency of visits by guests and customers,
- the building’s floor layout (e.g., the distance from a workstation to the restroom),
- and the number of work shifts.
In our experience, many companies choose to provide additional restrooms—especially for teams of more than 30 people or in multi-story buildings, where a single restroom per floor is not enough.
Minimum Dimensions for Toilets and Restroom Stalls
Compliance with regulations is not only a matter of the number of units, but also of the space in which they are located. Section 87 of the Regulation of the Minister of Infrastructure dated April 12, 2002, plays a key role here, as it specifies the minimum dimensions of restroom stalls in public buildings and workplaces.
According to the regulation, the minimum width of a toilet stall is 90 cm, and the depth is 120 cm. The door to the stall must be at least 80 cm wide and must open outward, which is important for both ergonomic and safety reasons (e.g., in emergency situations).
The toilet bowl should be installed at a height of 40–45 cm above the floor (in accordance with the PN-EN 33 standard), which ensures standard comfort for most users. The minimum distance between the center of the toilet bowl and the side wall should be at least 40 cm to allow for unobstructed use of the toilet.
Sufficient space should also be provided in front of the toilet bowl—regulations specify a minimum of 60 cm, but we know from experience that 75 cm or more significantly improves user comfort—especially in situations where the user has additional mobility limitations or is using the toilet with a child.
From a practical standpoint: in modern Class A office buildings, we recommend a minimum stall size of 100 cm x 150 cm. This allows for more comfortable use while still ensuring efficient use of space. For coed restrooms, fully enclosed stalls and increased space are absolutely essential.
Restroom for People with Disabilities – Technical Requirements
When designing a restroom for people with disabilities, there is no room for compromise. This is one of those places where strict compliance with regulations is just as important as understanding the user’s actual needs. Pursuant to § 86(2) of the Regulation of the Minister of Infrastructure dated April 12, 2002, every publicly accessible part of an office building must be equipped with at least one restroom adapted to the needs of people with disabilities.
The minimum usable area of such a room is 1.5 x 1.5 meters, which provides an adequate turning radius for a wheelchair—150 cm. This radius is necessary to allow for a full turn without having to move forward.
The width of the entrance door should be at least 90 cm, and the door itself must not have a threshold—even a small threshold can be an insurmountable obstacle for a person in a wheelchair. The door should open outward or be a sliding door so as not to restrict the space inside the cabin.
The toilet bowl must be positioned at a height of 45–50 cm, measured from the floor to the top edge. This height range makes it easier to transfer from a wheelchair and ensures a more natural posture while using the toilet.
Grab bars are also required—at least two, mounted on both sides of the toilet seat, at a height of 70–80 cm from the floor. They should be stable, preferably foldable, and slip-resistant. These features often determine whether a person with limited mobility can use the toilet independently.
It’s also important to ensure that the sink is properly positioned—ideally, it should be located across from or next to the toilet, with enough space to maneuver and without a cabinet underneath, so that a person in a wheelchair can comfortably roll up to it and use it.
Showers, sinks, and hygiene-supporting products
In office spaces, there isn’t always a requirement to install showers, but there are situations in which they become essential. According to Sections 22–23 of the Occupational Safety and Health Regulation, showers must be provided in facilities where the nature of the work causes significant soiling of the body or clothing, or where there is contact with hazardous substances. This applies, among others, to manufacturing companies, laboratories, workshops, and certain heavy industries.
The regulations clearly state: at least one shower for every 8 people who need to use it during work hours. This number must be adjusted for shift schedules; for example, if eight people finish their shift at the same time, at least one shower should be available. In the case of two shifts, the number of showers required remains the same, but their availability must be ensured during both time periods.
The minimum width of the shower entrance is 80 cm, which allows people with limited mobility to enter safely. The shower stall itself should measure at least 90×90 cm, and if it is intended for people with disabilities, it should measure at least 100×100 cm, with additional space for changing and a seat.
When it comes to complementary elements, it’s worth paying attention to the details:
- Toilet paper should be placed 60–70 cm above the floor and about 20–25 cm from the front edge of the toilet seat—so that it is easily accessible while seated.
- Sinks should be positioned so that the distance from the side wall is at least 20 cm, which ensures ease of use. It is recommended to leave a gap of at least 60 cm between sinks, and the installation height should be approximately 85 cm.
All of these guidelines—though technical—translate into the actual quality of the restroom experience. A well-designed office restroom is more than just a legal requirement. It demonstrates that the employer understands the diverse needs of employees and takes them seriously.
Coed Restrooms—How to Do It Legally?
Coed restrooms continue to stir up a lot of controversy in Poland; however, from the perspective of regulations and best design practices, they are an acceptable solution—provided that certain technical and organizational requirements are met. Pursuant to § 26(3) of the Regulation of the Minister of Labor and Social Policy dated September 26, 1997, companies employing up to five people of the same sex may use shared restroom facilities. In practice, this means it is possible to design a coed restroom, but only if it meets specific standards for privacy, accessibility, and hygiene.
The most important requirement is the use of fully enclosed cubicles—that is, those with walls and doors extending from floor to ceiling—which eliminate visual gaps and ensure complete privacy for the user. Such enclosures must be sturdy, mechanically ventilated, and made of materials resistant to moisture and cleaning agents. Solutions such as “half-wall” partitions or stalls with open spaces above and below the door are unacceptable in unisex restrooms.
Another requirement is an appropriate ratio of sinks to stalls. The minimum standard is one sink for every two stalls, but for higher traffic volumes, we recommend considering one sink for each stall—especially if the restroom is also used by guests or outside customers.
It’s also important not to overlook clear signage—neutral, yet unambiguous. In practice, graphic symbols work best, such as silhouettes of people without gender markers or a simple restroom pictogram. Instead of the terms “women’s” and “men’s,” it’s better to use messages such as “unisex restroom” or “all-gender restroom”—a gender-neutral solution that enhances the inclusivity of the space.
A shared restroom also requires effective mechanical ventilation—not only for odor control but also to comply with health and safety regulations. The room should be equipped with supply and exhaust ventilation, preferably automatically controlled or motion-activated.
Important note: A restroom for people with disabilities cannot be located within the same coeducational space. It must be a separate room—fully equipped to meet the needs of users with limited mobility, in accordance with § 86(2) of the WT.
Coed restrooms can be an excellent solution in small businesses, coworking spaces, or modern environments where efficient use of space and gender neutrality are priorities. However, to ensure they are legally compliant and comfortable for everyday use, they must be designed thoughtfully, with attention to every detail—from dimensions and materials to how they are used.
Summary
A well-designed restroom in the workplace is not just a matter of regulatory compliance, but has a real impact on employee comfort, health, and satisfaction. Knowledge of technical requirements, minimum dimensions, accessibility guidelines, and ergonomic standards allows for the creation of restroom facilities that are functional, safe, and tailored to the needs of all users—regardless of the number of employees, their gender, or their level of mobility. It is an element of infrastructure that reflects a company’s professionalism and its approach to people.